P0032low severityPowertrain

HO2S Heater Control Circuit High Bank 1 Sensor 1

on 2016 Acura ILX 2.4L I4 · FWD

What this code means

The voltage in the Bank 1 Sensor 1 O2 heater circuit is higher than expected.

Symptoms

  • Check Engine Light
  • Possible heater staying on too long

Common causes

  • Short to power in heater circuit
  • Faulty O2 sensor
  • Relay stuck closed

Diagnostic steps

  1. Test heater circuit voltage
  2. Check for shorts to power
  3. Test sensor heater resistance

Repair notes

Repair short to power or replace O2 sensor.