Back to 2001 Audi A6

2001 AUDI A6

2.7L Turbo V6AWDAUTOMATICgasturbo
7 active safety recalls on this vehicle — view recalls
Repairs0Labor500Torque2499Fluid9DTC679Battery0Maintenance0Recalls7
P0130moderate severityPowertrain

O2 Sensor Circuit Bank 1 Sensor 1

on 2001 Audi A6 2.7L Turbo V6 · AWD

What this code means

General malfunction in the upstream oxygen sensor circuit for Bank 1.

Symptoms

  • Check Engine Light
  • Poor fuel economy
  • Rough idle
  • Failed emissions

Common causes

  • Faulty O2 sensor
  • Exhaust leak near sensor
  • Wiring damage
  • Fuel system issue affecting sensor

Diagnostic steps

  1. Test O2 sensor signal voltage (should oscillate 0.1-0.9V)
  2. Check for exhaust leaks
  3. Inspect wiring
  4. Monitor sensor response time

Repair notes

Replace O2 sensor. Check for exhaust leaks first.