P0341high severityPowertrain

Camshaft Position Sensor A Circuit Range/Performance Bank 1

on 2000 Mitsubishi GTO 3.0L V6 NA 6G72 · AWD

What this code means

CMP sensor A Bank 1 signal is out of expected pattern.

Symptoms

  • Check Engine Light
  • Rough running
  • Poor performance

Common causes

  • Sensor issue
  • Timing chain stretch
  • Reluctor ring damage

Diagnostic steps

  1. Scope CMP signal
  2. Check timing chain
  3. Inspect sensor

Repair notes

Check timing components. Replace sensor.