Back to 2023 Tesla Model S

2023 TESLA MODEL S

Plaid Tri Motor AWDAWDAUTOMATICev
12 active safety recalls on this vehicle — view recalls
Repairs0Labor406Torque5220Fluid8DTC557Battery0Maintenance0Recalls12
B2302low severityBody

Surround View System Calibration

on 2023 Tesla Model S Plaid Tri Motor AWD · AWD

What this code means

The surround/360-degree view camera system requires recalibration after camera replacement or windshield service.

Symptoms

  • Surround view image stitching incorrect
  • Bird eye view distorted
  • Camera views not aligned
  • Calibration warning on display

Common causes

  • Camera replaced without recalibration
  • Camera mounting shifted
  • Windshield camera angle changed
  • Software update required
  • Vehicle alignment changed

Diagnostic steps

  1. Attempt surround view calibration procedure
  2. Verify all cameras are properly mounted
  3. Check calibration target positioning
  4. Use dealer calibration tool
  5. Verify camera mounting angles

Repair notes

Perform surround view camera calibration using manufacturer procedure and calibration targets.