Back to 2005 Ford Ranger

2005 FORD RANGER

4.0L V6 SOHC4WDAUTOMATICgas
11 active safety recalls on this vehicle — view recalls
Repairs0Labor593Torque3791Fluid9DTC853Battery1Maintenance0Recalls11
P0136moderate severityPowertrain

O2 Sensor Circuit Bank 1 Sensor 2

on 2005 Ford Ranger 4.0L V6 SOHC · 4WD

What this code means

General malfunction in the downstream O2 sensor circuit for Bank 1.

Symptoms

  • Check Engine Light
  • Failed emissions test
  • Reduced catalyst monitoring

Common causes

  • Faulty downstream O2 sensor
  • Wiring damage
  • Exhaust leak after catalyst

Diagnostic steps

  1. Test O2 sensor voltage
  2. Inspect wiring
  3. Check for exhaust leaks after cat

Repair notes

Replace downstream O2 sensor.