Back to 2016 Cadillac SRX

2016 CADILLAC SRX

2.8L Turbo V6FWDAUTOMATICgasturbo
1 active safety recall on this vehicle — view recalls
Repairs0Labor595Torque2395Fluid6DTC960Battery0Maintenance0Recalls1
P0158moderate severityPowertrain

O2 Sensor Circuit High Voltage Bank 2 Sensor 2

on 2016 Cadillac SRX 2.8L Turbo V6 · FWD

What this code means

High voltage from the downstream O2 sensor on Bank 2.

Symptoms

  • Check Engine Light
  • May indicate catalyst failure

Common causes

  • Faulty sensor
  • Catalyst failure
  • Rich condition

Diagnostic steps

  1. Test voltage
  2. Check catalyst

Repair notes

Replace sensor or catalyst.

Other Powertrain codes on this vehicle

Building an app?
Free API access to all this data — 50 requests/day, no card required.
Get an API key →
Run a shop?
Manage repairs, estimates, and customers with ShopBase — $249/mo, all features included.
Try ShopBase →