Back to 2017 Chrysler 300

2017 CHRYSLER 300

3.6L V6 PentastarRWDAUTOMATICgas
2 active safety recalls on this vehicle — view recalls
Repairs0Labor505Torque5967Fluid7DTC922Battery0Maintenance0Recalls2
P0152moderate severityPowertrain

O2 Sensor Circuit High Voltage Bank 2 Sensor 1

on 2017 Chrysler 300 3.6L V6 Pentastar · RWD

What this code means

The upstream O2 sensor voltage on Bank 2 is staying high.

Symptoms

  • Check Engine Light
  • Rich running Bank 2
  • Black smoke

Common causes

  • Faulty sensor
  • Leaking injector Bank 2
  • High fuel pressure

Diagnostic steps

  1. Monitor sensor voltage
  2. Check injectors
  3. Test fuel pressure

Repair notes

Replace sensor or fix rich condition.