B0601

Blower Motor Resistor Circuit

2011-2014 Dodge Avenger 3.6L V6 Pentastar

Low SeverityBodyGeneric (SAE)

Description

Malfunction in the blower motor resistor or speed control module. The resistor controls blower speed at lower settings.

Symptoms

  • Blower only works on highest speed
  • No blower at low/medium settings
  • Blower speed inconsistent

Common Causes

  • Faulty blower resistor
  • Thermal fuse in resistor blown
  • Corroded resistor connector
  • Excessive current from failing blower motor

Diagnostic Steps

  1. Test blower resistor resistance at each tap
  2. Check thermal fuse continuity
  3. Inspect resistor connector
  4. Measure blower motor current draw

Repair Notes

Replace blower motor resistor. If resistor keeps failing, check blower motor current draw as a failing motor can burn resistors.

Related Codes

B0600Blower Motor Circuit MalfunctionB0602Blower Motor Control Module Circuit

Other Body Codes

B0601 on Other Vehicles

Common Questions

What does code B0601 mean on a 2011-2014 Dodge Avenger?

B0601 stands for "Blower Motor Resistor Circuit". Malfunction in the blower motor resistor or speed control module. The resistor controls blower speed at lower settings.

What are the symptoms of B0601 on a Dodge Avenger?

Common symptoms of B0601 include: Blower only works on highest speed, No blower at low/medium settings, Blower speed inconsistent.

What causes B0601 on a 2011-2014 Dodge Avenger?

Common causes of B0601 include: Faulty blower resistor, Thermal fuse in resistor blown, Corroded resistor connector, Excessive current from failing blower motor.

View Labor Times | View Torque Specs | View Fluid Specs