P0138moderate severityPowertrain

O2 Sensor Circuit High Voltage Bank 1 Sensor 2

on 2006 Dodge Charger 2.7L V6 · AWD

What this code means

The downstream O2 sensor on Bank 1 is reading high voltage consistently.

Symptoms

  • Check Engine Light
  • Failed emissions
  • May indicate catalyst failure

Common causes

  • Faulty sensor
  • Catalytic converter failure
  • Rich running condition

Diagnostic steps

  1. Test sensor voltage
  2. Check catalyst efficiency
  3. Monitor upstream vs downstream O2 patterns

Repair notes

Replace sensor. If catalyst failed, replace catalytic converter.