P0041moderate severityPowertrain

O2 Sensor Signals Swapped Bank 1 Sensor 2 / Bank 2 Sensor 2

on 1996 Lexus LS 400 4.0L V8 · RWD

What this code means

The downstream O2 sensor signals for Bank 1 and Bank 2 appear to be swapped.

Symptoms

  • Check Engine Light
  • Incorrect catalyst monitoring
  • Failed emissions

Common causes

  • Sensor connectors swapped
  • Wiring crossed after service

Diagnostic steps

  1. Verify downstream sensor connections
  2. Trace wiring to PCM

Repair notes

Correct the sensor connector routing.