Blower Motor Resistor Circuit
2007-2012 Nissan Altima 2.5L I4
Description
Malfunction in the blower motor resistor or speed control module. The resistor controls blower speed at lower settings.
Symptoms
- Blower only works on highest speed
- No blower at low/medium settings
- Blower speed inconsistent
Common Causes
- Faulty blower resistor
- Thermal fuse in resistor blown
- Corroded resistor connector
- Excessive current from failing blower motor
Diagnostic Steps
- Test blower resistor resistance at each tap
- Check thermal fuse continuity
- Inspect resistor connector
- Measure blower motor current draw
Repair Notes
Replace blower motor resistor. If resistor keeps failing, check blower motor current draw as a failing motor can burn resistors.
Related Codes
Other Body Codes
- B0001Driver Frontal Stage 1 Deployment Control
- B0002Driver Frontal Stage 2 Deployment Control
- B0003Passenger Frontal Stage 1 Deployment Control
- B0004Passenger Frontal Stage 2 Deployment Control
- B0005Driver Knee Airbag Deployment Circuit
- B0006Passenger Knee Airbag Deployment Circuit
- B0007Rear Left Side Airbag Deployment Circuit
- B0008Rear Right Side Airbag Deployment Circuit
- B0010Driver Side Airbag Deployment
- B0011Driver Side Airbag Deployment Circuit Open
B0601 on Other Vehicles
Nissan 200SX
1995-1998 1.6L I4 GA16DE
Nissan 200SX SE-R
1995-1998 2.0L I4 SR20DE
Nissan 240SX
1995-1998 2.4L I4 KA24DE
Nissan 300ZX
1990-1996 3.0L V6 VG30DE
Nissan 300ZX Twin Turbo
1990-1996 3.0L Twin-Turbo V6 VG30DETT
Nissan 350Z
2003-2006 3.5L V6 VQ35DE
Nissan 350Z
2007-2009 3.5L V6 VQ35HR
Nissan 370Z
2009-2020 3.7L V6 VQ37VHR
Common Questions
What does code B0601 mean on a 2007-2012 Nissan Altima?
B0601 stands for "Blower Motor Resistor Circuit". Malfunction in the blower motor resistor or speed control module. The resistor controls blower speed at lower settings.
What are the symptoms of B0601 on a Nissan Altima?
Common symptoms of B0601 include: Blower only works on highest speed, No blower at low/medium settings, Blower speed inconsistent.
What causes B0601 on a 2007-2012 Nissan Altima?
Common causes of B0601 include: Faulty blower resistor, Thermal fuse in resistor blown, Corroded resistor connector, Excessive current from failing blower motor.