P0139low severityPowertrain

O2 Sensor Circuit Slow Response Bank 1 Sensor 2

on 2006 Toyota Camry 3.0L V6 · FWD

What this code means

The downstream O2 sensor on Bank 1 is responding too slowly.

Symptoms

  • Check Engine Light
  • Failed emissions

Common causes

  • Aging sensor
  • Contaminated sensor
  • Catalyst issue

Diagnostic steps

  1. Monitor sensor response
  2. Check catalyst efficiency

Repair notes

Replace downstream O2 sensor.