P0158moderate severityPowertrain

O2 Sensor Circuit High Voltage Bank 2 Sensor 2

on 2003 Audi S6 4.2L V8 · FWD

What this code means

High voltage from the downstream O2 sensor on Bank 2.

Symptoms

  • Check Engine Light
  • May indicate catalyst failure

Common causes

  • Faulty sensor
  • Catalyst failure
  • Rich condition

Diagnostic steps

  1. Test voltage
  2. Check catalyst

Repair notes

Replace sensor or catalyst.