Back to 2012 Tesla Roadster

2012 TESLA ROADSTER

Single Motor RWDRWDAUTOMATICev
Repairs87Labor371Torque4084Fluid6DTC550Battery0Maintenance0Recalls0
P0346high severityPowertrain

Camshaft Position Sensor A Circuit Range/Performance Bank 2

on 2012 Tesla Roadster Single Motor RWD · RWD

What this code means

CMP sensor A Bank 2 signal out of range.

Symptoms

  • Check Engine Light
  • Rough running

Common causes

  • Sensor issue
  • Timing chain
  • Reluctor damage

Diagnostic steps

  1. Scope signal
  2. Check timing

Repair notes

Replace sensor or repair timing.