Back to 2011 Audi A4

2011 AUDI A4

2.0L Turbo I4AWDAUTOMATICgasturbo
Repairs0Labor595Torque3527Fluid9DTC894Battery0Maintenance0Recalls0
P0154moderate severityPowertrain

O2 Sensor Circuit No Activity Bank 2 Sensor 1

on 2011 Audi A4 2.0L Turbo I4 · AWD

What this code means

No switching activity from the upstream O2 sensor on Bank 2.

Symptoms

  • Check Engine Light
  • Poor fuel economy

Common causes

  • Faulty sensor
  • Heater failure
  • Wiring open

Diagnostic steps

  1. Test sensor signal
  2. Check heater
  3. Inspect wiring

Repair notes

Replace O2 sensor.

Other Powertrain codes on this vehicle