P2204moderate severityPowertrain

NOx Sensor Circuit Intermittent Bank 1

on 1996 Audi A6 2.8L V6 · AWD

What this code means

Intermittent signal from the NOx sensor on bank 1.

Symptoms

  • Intermittent check engine light
  • Erratic SCR operation

Common causes

  • Loose connection
  • Damaged wiring
  • Sensor connector moisture ingress

Diagnostic steps

  1. Wiggle test wiring and connector
  2. Check for water intrusion
  3. Monitor signal stability

Repair notes

Clean and secure connector. Replace sensor or repair wiring if intermittent.