B0625low severityBody

Recirculation Door Actuator Circuit

on 2001 Audi A6 2.7L Turbo V6 · AWD

What this code means

Malfunction in the HVAC recirculation door actuator. This door switches between outside air and recirculated cabin air.

Symptoms

  • Cannot switch to recirculation mode
  • Recirculation button unresponsive
  • Outside odors entering cabin in recirc mode
  • Clicking noise near glove box

Common causes

  • Faulty recirc actuator
  • Door binding
  • Actuator gear stripped
  • Wiring issue

Diagnostic steps

  1. Test recirc actuator operation
  2. Check door movement
  3. Inspect actuator gears
  4. Test wiring
  5. Scan HVAC codes

Repair notes

Replace recirculation door actuator.