What this code means

The tachometer gauge is not functioning or displays incorrect RPM readings.

Symptoms

  • Tachometer reads zero
  • Tachometer needle erratic
  • Tachometer bouncing at idle
  • Gauge needle stuck

Common causes

  • Instrument cluster stepper motor failure
  • Cluster circuit board fault
  • RPM signal issue from PCM
  • Wiring problem

Diagnostic steps

  1. Check RPM signal from PCM with scan tool
  2. Test tachometer stepper motor
  3. Inspect cluster circuit board
  4. Check wiring from PCM to cluster

Repair notes

Replace instrument cluster stepper motor or circuit board.