Back to 2007 Cadillac SRX

2007 CADILLAC SRX

3.6L V6AWDAUTOMATICgas
1 active safety recall on this vehicle — view recalls
Repairs0Labor1000Torque4939Fluid16DTC1772Battery0Maintenance0Recalls1
P0157moderate severityPowertrain

O2 Sensor Circuit Low Voltage Bank 2 Sensor 2

on 2007 Cadillac SRX 3.6L V6 · AWD

What this code means

Low voltage from the downstream O2 sensor on Bank 2.

Symptoms

  • Check Engine Light

Common causes

  • Faulty sensor
  • Short to ground
  • Exhaust leak

Diagnostic steps

  1. Test voltage
  2. Check for shorts

Repair notes

Replace sensor.

Other Powertrain codes on this vehicle

Building an app?
Free API access to all this data — 50 requests/day, no card required.
Get an API key →
Run a shop?
Manage repairs, estimates, and customers with ShopBase — $249/mo, all features included.
Try ShopBase →