P0337high severityPowertrain

Crankshaft Position Sensor A Circuit Low Input

on 2006 Isuzu Ascender 4.2L I6 · 4WD

What this code means

Low or no signal from CKP sensor.

Symptoms

  • No start
  • Stalling
  • Erratic tachometer

Common causes

  • Faulty sensor
  • Short to ground
  • Wiring open
  • Corroded connector

Diagnostic steps

  1. Test sensor signal
  2. Check for shorts
  3. Inspect wiring and connector

Repair notes

Replace CKP sensor or repair wiring.