P0141low severityPowertrain

O2 Sensor Heater Circuit Bank 1 Sensor 2

on 2009 Audi Q7 3.6L V6 · AWD

What this code means

Malfunction in the downstream O2 sensor heater circuit for Bank 1.

Symptoms

  • Check Engine Light
  • Failed emissions

Common causes

  • Faulty sensor heater
  • Blown fuse
  • Wiring damage

Diagnostic steps

  1. Check fuse
  2. Test heater resistance
  3. Inspect wiring

Repair notes

Replace O2 sensor or repair wiring.