Back to 2014 Cadillac SRX

2014 CADILLAC SRX

3.0L V6AWDAUTOMATICgas
2 active safety recalls on this vehicle — view recalls
Repairs0Labor515Torque4985Fluid9DTC955Battery0Maintenance0Recalls2
P0040moderate severityPowertrain

O2 Sensor Signals Swapped Bank 1 Sensor 1 / Bank 2 Sensor 1

on 2014 Cadillac SRX 3.0L V6 · AWD

What this code means

The PCM has determined that the upstream O2 sensor signals for Bank 1 and Bank 2 are swapped, likely due to incorrect wiring after sensor replacement.

Symptoms

  • Check Engine Light
  • Poor fuel economy
  • Rough running
  • Failed emissions

Common causes

  • O2 sensor connectors swapped after service
  • Wiring crossed between banks
  • Incorrect sensor installation

Diagnostic steps

  1. Verify which O2 sensor is connected to which bank
  2. Trace wiring from each sensor to PCM connector
  3. Check for crossed connectors

Repair notes

Swap the sensor connectors to the correct banks.