Back to 2021 Lincoln Aviator

2021 LINCOLN AVIATOR

3.0L Twin-Turbo V6RWDAUTOMATICgasturbo
26 active safety recalls on this vehicle — view recalls
Repairs0Labor597Torque3794Fluid7DTC968Battery0Maintenance0Recalls26
P3600low severityPowertrain

Auto Start-Stop System Malfunction

on 2021 Lincoln Aviator 3.0L Twin-Turbo V6 · RWD

What this code means

The automatic engine start-stop system has been disabled due to a detected fault. The system shuts off the engine at stops to save fuel.

Symptoms

  • Start-stop indicator shows fault
  • Engine does not shut off at stops
  • Start-stop disabled message on dash
  • Slightly higher fuel consumption
  • Start-stop light flashing

Common causes

  • Weak 12V battery
  • Battery sensor failure
  • Starter motor wear
  • Engine temperature out of range
  • Brake vacuum insufficient

Diagnostic steps

  1. Read start-stop system status and inhibit reasons
  2. Test 12V battery state of health
  3. Check IBS (intelligent battery sensor)
  4. Monitor brake vacuum level
  5. Check starter motor engagement count

Repair notes

Replace 12V battery if state of health is low. Register new battery with BMS. Replace IBS if faulty.