Back to 2017 Subaru Legacy

2017 SUBARU LEGACY

3.6L H6AWDCVTgas
2 active safety recalls on this vehicle — view recalls
Repairs0Labor505Torque3898Fluid9DTC917Battery0Maintenance0Recalls2
P0140moderate severityPowertrain

O2 Sensor Circuit No Activity Bank 1 Sensor 2

on 2017 Subaru Legacy 3.6L H6 · AWD

What this code means

The downstream O2 sensor on Bank 1 shows no switching activity.

Symptoms

  • Check Engine Light
  • No catalyst monitoring

Common causes

  • Faulty sensor
  • Heater circuit failure
  • Wiring open

Diagnostic steps

  1. Test sensor voltage
  2. Check heater
  3. Inspect wiring

Repair notes

Replace downstream O2 sensor.

Other Powertrain codes on this vehicle

Building an app?
Free API access to all this data — 50 requests/day, no card required.
Get an API key →
Run a shop?
Manage repairs, estimates, and customers with ShopBase — $249/mo, all features included.
Try ShopBase →