P2202moderate severityPowertrain

NOx Sensor Circuit Low Bank 1

on 2005-2011 Audi A6 4.2L V8 · AWD

What this code means

NOx sensor bank 1 signal is below minimum expected voltage.

Symptoms

  • Check engine light
  • Incorrect DEF injection rate

Common causes

  • Sensor short to ground
  • Wiring fault
  • Failed sensor

Diagnostic steps

  1. Measure signal voltage
  2. Check wiring for shorts to ground

Repair notes

Repair wiring or replace NOx sensor.