exhaust
Flex Pipe
for 2021 Mercedes-Benz G-Class 4.0L Turbo V8 · 4WD
Difficulty
Advanced
Time
2.7 h
Tools
11
Steps
14
✓Fact-checked. Built from OLP's spec database, then independently fact-checked line by line with every correction applied. Master-tech sign-off by Chris Hackleman is queued. Cross-check torque values against the factory manual, and stop if anything looks unsafe. How our data is made.
Remove and replace the exhaust flex pipe assembly on the 2019 Mercedes-Benz G-Class with 4.0L Turbo V8 engine, including disconnection of oxygen sensors and exhaust hangers.
Warnings
⚠️Allow exhaust system to cool completely (minimum 2 hours after engine shutdown) to prevent severe burns. Exhaust components retain heat for extended periods.
⚠️Exhaust components are under the vehicle. Ensure vehicle is properly supported on jack stands rated for the vehicle weight. Never work under a vehicle supported only by a jack.
⚠Oxygen sensor threads are fragile and seize easily. Apply penetrating oil and allow to soak before removal. Do not force seized sensors.
⚠Exhaust fasteners may be severely corroded. Inspect all hardware and replace as needed to prevent breakage during reassembly.
ℹ️This procedure may trigger oxygen sensor fault codes. Have an OBD-II scanner available to clear codes after completion.
Tools required
Torx driver set (T20-T50)Essential
E-Torx socket set (E10-E18)Essential
Torque wrench (10-100 Nm range)Essential
Penetrating oilEssential
Anti-seize compound (nickel-based)Essential
As an Amazon Associate and Autel/ANCEL partner, OLP earns from qualifying purchases — how we link. This never changes the specs we publish.
Parts
- Exhaust flex pipe assembly × 1 — Use OEM specification
- Exhaust flange gaskets × 2 — Use OEM specification
- Flange bolts/nuts (if corroded) × 6 — M10 x 1.5mm
As an Amazon Associate and Autel/ANCEL partner, OLP earns from qualifying purchases — how we link. This never changes the specs we publish.
Preparation
- Park vehicle on level surface and allow exhaust system to cool completely for minimum 2 hours.
- Raise vehicle on lift or safely support on jack stands at manufacturer-specified lift points. Ensure minimum 24 inches of working clearance beneath vehicle.
- Visually inspect flex pipe location in exhaust system. On the 2019 G-Class 4.0L V8, the flex pipe is located between the front catalytic converters and the mid-pipe section.
- Apply penetrating oil to all visible exhaust flange bolts, oxygen sensor threads, and hanger mounting points. Allow to soak for 15-30 minutes.
- Disconnect negative battery terminal to prevent accidental oxygen sensor heater circuit damage during removal.
Procedure
- 1Disconnect oxygen sensorsLocate the downstream oxygen sensors mounted in or near the flex pipe section. Disconnect the electrical connectors by pressing the release tab and pulling away from the sensor body. If sensors are mounted in the flex pipe itself, they must be removed. Using an oxygen sensor socket with wire slot (verify hex size, commonly 22mm), carefully unthread the oxygen sensors counterclockwise. Work slowly to avoid breaking sensor threads in the exhaust bung. If resistance is high, apply additional penetrating oil and allow to soak.
- 2Remove upstream flange connectionLocate the forward flange connection between the catalytic converter outlet and the flex pipe inlet. Remove the flange fasteners securing this connection (count and type per MB documentation; commonly 2-3 bolts or spring-loaded studs) using the appropriate E-Torx or Torx socket. Note the orientation and position of any alignment dowels or guides in the flange. Once fasteners are removed, gently separate the flange joint. The old gasket will likely remain stuck to one or both flanges.
- 3Remove downstream flange connectionLocate the rear flange connection between the flex pipe outlet and the mid-pipe inlet. Remove the flange fasteners securing this connection (count and type per MB documentation; commonly 2-3 bolts or spring-loaded studs). Work carefully as these fasteners are often more corroded due to their location further back in the system. Once fasteners are removed, gently separate the flange joint.
- 4Disconnect exhaust hangersIdentify all rubber exhaust hangers supporting the flex pipe section. On this platform, there are typically 2 hanger points on the flex pipe assembly. Using an exhaust hanger removal tool or pry bar, carefully work each rubber hanger off its mounting bracket. Pull the hanger away from the vehicle body-mounted hook while supporting the exhaust pipe weight. Do not cut hangers unless they are being replaced.
- 5Remove flex pipe assemblyWith all connections and hangers disconnected, carefully lower and maneuver the flex pipe assembly out from under the vehicle. The assembly may be restricted by surrounding components, heat shields, or crossmembers. Rotate and angle the pipe as needed for clearance. Once clear, place the old assembly aside for inspection and comparison with the new part.
- 6Clean flange surfaces and inspect mounting pointsUsing a wire brush, thoroughly clean both mating flange surfaces on the catalytic converter outlet and mid-pipe inlet. Remove all traces of old gasket material, carbon buildup, and corrosion to ensure a proper seal. Inspect flange surfaces for warping, cracks, or damage. Check all exhaust hanger mounting points on the vehicle body for damage or excessive wear. Inspect oxygen sensor bungs in adjacent sections for thread damage if sensors will be reinstalled in different locations.
- 7Prepare new flex pipe assemblyUnpack the new flex pipe assembly and verify it matches the original part in length, flange configuration, oxygen sensor bung locations, and hanger positions. If oxygen sensors are being reused, inspect sensor threads and apply a thin coat of nickel-based anti-seize compound to the threads (avoid getting anti-seize on the sensor tip). If sensors are being installed in the new flex pipe, hand-thread them into the bungs at this stage to ensure proper fitment before installation.
- 8Install new flex pipe assemblyPosition the new flex pipe assembly under the vehicle, aligning it with the upstream and downstream flange connections. Maneuver the assembly into position, working carefully around heat shields and structural components. Loosely engage the rubber exhaust hangers onto their body-mounted hooks. The hangers should support the assembly weight but allow movement for flange alignment.
- 9Install new flange gaskets and connect upstream flangePlace a new exhaust flange gasket onto the catalytic converter outlet flange, ensuring any alignment dowels or guides engage properly. Align the flex pipe inlet flange to the catalytic converter outlet flange. Insert the 3 flange bolts or nuts and hand-tighten only at this stage. Verify the flanges are properly seated and aligned before proceeding.
- 10Connect downstream flangePlace a new exhaust flange gasket onto the mid-pipe inlet flange. Align the flex pipe outlet flange to the mid-pipe inlet flange, adjusting the position of the entire assembly as needed. Insert the 3 flange bolts or nuts and hand-tighten. Check that the entire flex pipe assembly is properly positioned with no binding or excessive tension on the flex section.
- 11Torque flange fastenersUsing a torque wrench, tighten all flange bolts/nuts in a crisscross pattern to ensure even loading. Torque the upstream flange fasteners (catalytic converter to flex pipe) to the Mercedes-Benz specified value, then torque the downstream flange fasteners (flex pipe to mid-pipe) to the specified value. Confirm exact torque figures in MB service documentation before tightening. Verify all fasteners are properly seated and torqued.
- 12Verify hanger positioning and adjust alignmentCheck that all rubber exhaust hangers are fully seated on their mounting brackets and that the exhaust system hangs with proper clearance from surrounding components. The flex pipe should have adequate clearance from the driveshaft, suspension components, fuel lines, and heat shields. Adjust hanger positions if needed to achieve proper clearance and prevent contact during suspension travel.
- 13Install oxygen sensorsIf oxygen sensors were removed from the flex pipe during disassembly, install them now. Apply a thin coat of nickel-based anti-seize to sensor threads if not already done. Thread sensors into their bungs by hand until finger-tight, then use the oxygen sensor socket to torque them to the Mercedes-Benz specified value (commonly ~40-50 Nm; verify in documentation). Note that many OEM sensors ship with pre-coated threads and should not receive additional anti-seize. Be careful not to over-torque as this can damage the sensor or strip the exhaust bung threads. Reconnect all oxygen sensor electrical connectors, ensuring the locking tabs click into place.Torque specO2 Sensor55 Nm (40 lb-ft)
- 14Final inspection and battery reconnectionPerform a final visual inspection of all connections, ensuring flange bolts are tight, oxygen sensors are secure, electrical connectors are engaged, and exhaust hangers are properly seated. Check for adequate clearance around the entire flex pipe assembly. Reconnect the negative battery terminal. Lower the vehicle from the lift or jack stands.
Reassembly
- Installation follows removal in reverse order with new gaskets at all flange connections.
- Always use new exhaust flange gaskets; do not reuse old gaskets.
- Torque all flange fasteners in a crisscross pattern to ensure even loading and prevent leaks.
- Apply nickel-based anti-seize to oxygen sensor threads before installation to prevent future seizing.
Verification
- Start the engine and allow it to idle. Listen for exhaust leaks at both flange connections. A leak will produce a distinct ticking or hissing sound that increases with engine RPM.
- Check for visible exhaust gases escaping from flange joints. Minor smoke from residual oils burning off is normal for the first few minutes.
- Verify oxygen sensor electrical connections are secure by checking for diagnostic trouble codes using an OBD-II scanner. Clear any stored codes related to oxygen sensor disconnection.
- Test drive the vehicle and listen for any exhaust rattles, vibrations, or contact with surrounding components during acceleration, deceleration, and over bumps.
- After the first 50-100 miles of driving, re-inspect flange bolts for proper torque as thermal cycling can cause slight settling. Re-torque if necessary.