electrical
Blower Motor Control Module
for 2017 Dodge Viper 8.4L V10 · RWD
Difficulty
Easy
Time
54 min
Tools
4
Steps
10
✓Fact-checked. Built from OLP's spec database, then independently fact-checked line by line with every correction applied. Master-tech sign-off by Chris Hackleman is queued. Cross-check torque values against the factory manual, and stop if anything looks unsafe. How our data is made.
Remove and replace the blower motor control module (also known as the blower motor resistor or power module) located in the HVAC system to restore proper climate control fan operation.
Warnings
⚠The blower motor control module may be hot if the blower has been running recently. Allow time to cool before handling.
ℹ️The module is located in the passenger footwell area and may require contortion to access comfortably.
Tools required
As an Amazon Associate and Autel/ANCEL partner, OLP earns from qualifying purchases — how we link. This never changes the specs we publish.
Parts
- Blower motor control module × 1 — Use OEM specification
As an Amazon Associate and Autel/ANCEL partner, OLP earns from qualifying purchases — how we link. This never changes the specs we publish.
Preparation
- Ensure the vehicle is parked on level ground with the engine off and ignition key removed
- Allow the climate control system to cool if it has been in use recently
- Set the parking brake
Procedure
- 1Disconnect battery negative terminalDisconnect the negative battery terminal to prevent electrical shorts during the procedure. The battery is located in the engine compartment. Use a 10mm wrench or socket to loosen the negative terminal clamp and remove the cable from the battery post.
- 2Access passenger footwell areaMove the passenger seat fully rearward and upward to maximize access to the footwell area. The blower motor control module is mounted on the HVAC case on the passenger side, typically near the firewall below the glove box area.
- 3Locate the blower motor control moduleLying on your back in the passenger footwell, locate the blower motor control module. It is mounted to the side of the HVAC housing near the blower motor itself, with a multi-pin electrical connector attached. The module typically has cooling fins visible and is secured with fasteners.
- 4Disconnect electrical connectorPress the locking tab on the electrical connector and carefully pull the connector straight off the blower motor control module. Note the connector orientation for reinstallation. Do not force the connector; if it resists, verify the locking tab is fully released.
- 5Remove control module mounting fastenersRemove the fasteners securing the blower motor control module to the HVAC case. These are typically 2 screws accessible with a 7mm socket or nut driver. Support the module while removing the final fastener to prevent it from falling.
- 6Remove blower motor control moduleOnce the fasteners are removed, carefully withdraw the blower motor control module from its mounting location. Note the orientation and position of any sealing materials or gaskets for proper reinstallation of the new module.
- 7Install new blower motor control modulePosition the new blower motor control module in the mounting location, ensuring any sealing surfaces or gaskets are properly aligned. Verify the module is oriented correctly with the electrical connector terminal facing the proper direction for easy connection.
- 8Install mounting fastenersInstall and hand-tighten the 2 mounting fasteners, then snug them securely with the 7mm socket. Do not overtighten as the module housing may be plastic or the mounting points may be threaded into plastic. Fasteners should be firm but not torqued excessively.
- 9Reconnect electrical connectorAlign the electrical connector with the terminals on the blower motor control module and press firmly until the locking tab clicks into place. Gently tug on the connector to verify it is fully seated and locked.
- 10Reconnect batteryReturn to the engine compartment and reconnect the negative battery terminal. Tighten the terminal clamp securely with a 10mm wrench.
Reassembly
- Return the passenger seat to its original position
- Ensure all electrical connections are secure and no tools or parts have been left in the footwell area
Verification
- Turn the ignition to the ON position (engine does not need to be running)
- Test the blower motor at all fan speed settings (low, medium-low, medium, medium-high, and high) to verify proper operation at each speed
- Verify smooth operation with no unusual noise, hesitation, or failure to operate at any speed setting
- Test both heat and A/C modes to confirm the blower motor responds correctly in all climate control configurations
- Check for any burning smell or excessive heat from the module area during initial operation
Related trouble codes on this vehicle
Codes that commonly send this job to the bay — tap one for symptoms, causes, and diagnostic steps.
P0001Fuel Volume Regulator Control Circuit/OpenP0002Fuel Volume Regulator Control Circuit Range/PerformanceP0026Intake Valve Control Solenoid Circuit Range/Performance Bank 1P0027Exhaust Valve Control Solenoid Circuit Range/Performance Bank 1P0030HO2S Heater Control Circuit Bank 1 Sensor 1P0031HO2S Heater Control Circuit Low Bank 1 Sensor 1P0042HO2S Heater Control Circuit (Bank 1 Sensor 3)P0043HO2S Heater Control Circuit Low (Bank 1 Sensor 3)P0050HO2S Heater Control Circuit Bank 2 Sensor 1P0051HO2S Heater Control Circuit Low Bank 2 Sensor 1P0062HO2S Heater Control Circuit (Bank 2 Sensor 3)P0063HO2S Heater Control Circuit Low (Bank 2 Sensor 3)