hvac
AC Hose - Low Side
for 2023 Chevrolet Bolt EUV 65 kWh Single Motor FWD · FWD
Editorial review:Chris Hackleman — Master Technician · 20+ years
Difficulty
Moderate
Time
1.5 h
Tools
10
Steps
12
✓Expert-verified. Personally reviewed and approved by OLP's master technicians (Chris Hackleman — 20+ years each). Always follow the vehicle's factory service information and torque specs.
This procedure covers the removal and replacement of the low-side AC hose on a 2023 Chevrolet Bolt EUV, including refrigerant recovery, hose replacement, and system recharge.
Warnings
⚠️AC refrigerant can cause severe frostbite on contact with skin. Wear safety glasses and gloves at all times.
⚠️This vehicle operates on high voltage. Ensure the high voltage system is de-energized before working near electrical components.
⚠AC system must be properly recovered by certified equipment. Venting refrigerant to atmosphere is illegal.
⚠Use only the correct refrigerant type and amount specified for this vehicle. Overcharging can damage the compressor.
ℹ️New O-rings must be installed at all AC line connections. Reusing old O-rings will cause leaks.
Tools required
AC recovery/recharge machineEssential
Torque wrench (5-50 Nm range)Essential
10mm socket and ratchetEssential
13mm wrenchEssential
Line wrench setEssential
Safety glassesEssential
Nitrile glovesEssential
Clean shop towelsEssential
As an Amazon Associate and Autel/ANCEL partner, OLP earns from qualifying purchases — how we link. This never changes the specs we publish.
Parts
- AC Low Side Hose Assembly × 1 — Use OEM specification
- AC Line O-Ring Kit × 1 — R134a compatible O-rings
- PAG Oil for AC System × 1 — PAG 46 or as specified by compressor
As an Amazon Associate and Autel/ANCEL partner, OLP earns from qualifying purchases — how we link. This never changes the specs we publish.
Fluids
- R134a Refrigerant
Preparation
- Ensure vehicle is parked on level ground with parking brake engaged
- Turn off vehicle and remove 12V battery negative terminal to de-energize accessories
- Allow AC system to equalize pressure for at least 10 minutes if recently operated
- Verify you have EPA Section 609 certification or work under certified supervision for refrigerant handling
- Locate the low-side AC hose running from the accumulator/drier to the compressor inlet
Procedure
- 1Recover refrigerant from AC systemConnect AC recovery machine to the vehicle's service ports (low and high side). Follow the recovery machine's operating instructions to completely evacuate all refrigerant from the system. Record the amount of refrigerant and oil recovered for proper recharge. Wait for machine to indicate recovery is complete and system is at atmospheric pressure.
- 2Access low-side AC hoseOpen the hood and locate the low-side AC hose. On the Bolt EUV, this runs from the accumulator (located near the condenser on the passenger side) to the compressor inlet. Remove any plastic engine covers or air duct components that obstruct access to the hose connections. You may need to remove the cover screws securing plastic covers.Torque specCover Screws11 Nm (8 lb-ft)
- 3Disconnect low-side hose at accumulatorUsing a line wrench to prevent rounding, loosen the fitting connecting the low-side hose to the accumulator/drier. Once loose, unthread by hand and carefully separate the connection. Some residual oil may drip out, so have a drip pan ready. Cap or plug the accumulator port immediately to prevent contamination.
- 4Disconnect low-side hose at compressorLocate the connection point at the compressor inlet (typically on the lower front of the compressor). Using a line wrench, loosen the fitting and separate the hose from the compressor. Cap or plug the compressor inlet port immediately to prevent moisture and debris entry. Allow any residual oil to drain into the drip pan.
- 5Remove mounting brackets if equippedIf the low-side hose is secured by any mounting brackets or clips along its routing path, remove the mounting bolts or release the clips. Note the exact routing and bracket positions for correct reinstallation of the new hose.Torque specMounting Bracket Bolts24 Nm (18 lb-ft)
- 6Remove old O-rings and inspect portsUsing a pick or O-ring removal tool, carefully extract the old O-rings from both the accumulator and compressor ports. Inspect the sealing surfaces for damage, scoring, or debris. Clean the sealing surfaces with a lint-free cloth. Do not scratch or gouge the sealing surfaces.⚠Be extremely careful not to damage the aluminum sealing surfaces when removing old O-rings. Any scratches will cause refrigerant leaks.
- 7Prepare new AC hoseUnpack the new low-side AC hose assembly. Verify it matches the original hose routing and has the correct fittings. Install new O-rings (supplied in kit) onto the hose fittings. Lightly coat the new O-rings with fresh PAG oil (compatible with the system compressor type). This lubricates the O-rings and aids in sealing.
- 8Install new hose at compressorRemove the cap from the compressor inlet port. Guide the new hose fitting into position and hand-thread the connection to ensure proper alignment. Once hand-tight, use a torque wrench with line wrench to tighten the AC line fitting to specification. Do not over-tighten as this can damage the O-ring seal.Torque specAC Line Fittings20 Nm (15 lb-ft)
- 9Install new hose at accumulatorRemove the cap from the accumulator port. Route the hose along the original path, ensuring it does not contact hot surfaces or sharp edges. Hand-thread the fitting onto the accumulator until snug, then torque to specification using a torque wrench and line wrench.Torque specAC Line Fittings20 Nm (15 lb-ft)
- 10Secure mounting bracketsReinstall any mounting brackets or clips that secure the hose along its routing path. Ensure the hose routing matches the original configuration to prevent vibration or contact with other components. Torque mounting bracket bolts to specification if applicable.Torque specMounting Bracket Bolts24 Nm (18 lb-ft)
- 11Vacuum and leak test systemConnect the AC service machine to both service ports. Pull a vacuum on the system for at least 30 minutes to remove all air and moisture. The system should hold vacuum without rising pressure for at least 10 minutes after the pump stops. This confirms there are no leaks in the new connections.⚠If the system does not hold vacuum, there is a leak. Locate and repair before proceeding to recharge.
- 12Recharge AC systemUsing the AC service machine, recharge the system with the correct amount of R134a refrigerant as specified on the underhood label (typically near the condenser). Add the appropriate amount of fresh PAG oil to compensate for oil lost during recovery and hose replacement (typically 1-2 oz for hose replacement). Follow the service machine instructions for proper charging procedure.
Reassembly
- Reinstall any plastic covers or air ducts removed during access, torquing cover screws to specification
- Reconnect the 12V battery negative terminal
- Double-check that all AC line fittings are properly torqued and secure
- Ensure the new hose routing does not contact any moving parts or hot surfaces
Verification
- Start the vehicle and turn the AC system to maximum cooling
- Verify cold air is produced from the vents within 1-2 minutes
- Use an electronic leak detector to check all new connections for refrigerant leaks
- Monitor AC system performance for proper cooling and listen for unusual noises from the compressor
- Check that system pressures are within normal range using AC gauges (typically 25-45 PSI low side at idle)
- Verify no oil residue or refrigerant leakage appears at the new hose connections after 10 minutes of operation