hvac
AC Orifice Tube
for 2022 Rivian EDV 500 Dual Motor AWD (EDV) · AWD
Difficulty
Advanced
Time
4.0 h
Tools
12
Steps
12
✓Fact-checked. Built from OLP's spec database, then independently fact-checked line by line with every correction applied. Master-tech sign-off by Chris Hackleman is queued. Cross-check torque values against the factory manual, and stop if anything looks unsafe. How our data is made.
Replace the AC orifice tube in the air conditioning system to restore proper refrigerant flow and system performance.
Warnings
⚠️This vehicle uses high voltage systems. Ensure the high voltage battery is properly isolated before beginning work. Contact with high voltage components can cause severe injury or death.
⚠️R-1234yf refrigerant is mildly flammable. Keep away from open flames and hot surfaces. Use only approved recovery equipment designed for R-1234yf.
⚠AC system operates at high pressures. Never open the system without first recovering refrigerant using approved equipment.
⚠Contamination is critical in electric vehicle AC systems. Maintain absolute cleanliness throughout this procedure.
ℹ️This vehicle requires EPA-certified refrigerant handling equipment and technician certification to legally service the AC system.
Tools required
AC recovery and recharge machineEssential
Refrigerant scaleEssential
Torque wrenchEssential
Line disconnect tool setEssential
Orifice tube removal toolEssential
Vacuum pumpEssential
AC manifold gauge setEssential
Socket set (metric)Essential
Lint-free shop towelsEssential
As an Amazon Associate and Autel/ANCEL partner, OLP earns from qualifying purchases — how we link. This never changes the specs we publish.
Parts
- AC orifice tube × 1 — Use OEM specification
- AC line O-rings × 1 — Use OEM specification
- PAG oil for electric vehicle compressor × 1 — R-1234yf compatible
- R-1234yf refrigerant × 1 — As required by system capacity
As an Amazon Associate and Autel/ANCEL partner, OLP earns from qualifying purchases — how we link. This never changes the specs we publish.
Preparation
- Park vehicle on level surface and engage parking brake
- Disconnect the 12-volt auxiliary battery negative terminal and wait 2 minutes
- Open the Rivian service mode through the vehicle interface to disable high voltage system (consult service manual for exact procedure)
- Verify high voltage system is isolated using appropriate lockout/tagout procedures
- Connect AC recovery machine and verify it is approved for R-1234yf refrigerant
- Record the amount of refrigerant recovered for recharge reference
- Allow system to stabilize at ambient temperature for accurate pressure readings
Procedure
- 1Recover AC refrigerantConnect the AC recovery machine to the high and low side service ports. Follow the machine manufacturer's instructions to completely recover all R-1234yf refrigerant from the system. Record the amount recovered, as this will guide the recharge amount. Wait until the machine indicates recovery is complete and the system has reached zero pressure.
- 2Access the orifice tube locationOn the Rivian EDV 500, locate the liquid line between the condenser and evaporator. The orifice tube is typically installed in the inlet line at the evaporator or within a specialized fitting in the liquid line near the firewall. Remove any protective covers or panels necessary to access this connection point. Clean the area thoroughly to prevent contamination.
- 3Disconnect the liquid lineUsing the appropriate line disconnect tool, separate the liquid line at the connection point where the orifice tube is located. On Rivian systems, this is typically a spring-lock or quick-disconnect fitting. Apply gentle pressure with the disconnect tool while pulling the line apart. Have lint-free towels ready to catch any residual refrigerant oil.
- 4Remove the old orifice tubeUsing the orifice tube removal tool, carefully extract the old orifice tube from its housing. Insert the removal tool into the line, engage the tabs or edges of the orifice tube, and pull straight out. If the tube is stuck due to debris or corrosion, work it gently back and forth while pulling. Inspect the removed tube for debris or metal particles which indicate compressor damage.
- 5Inspect and clean the lineExamine the interior of both line connections for debris, metal particles, or contamination. If metal particles are present, the system requires flushing and the compressor may need replacement. Clean the connection surfaces with lint-free towels. Ensure no foreign material remains in the line that could contaminate the new orifice tube.
- 6Install new O-ringsRemove the old O-rings from both sides of the connection. Inspect the O-ring sealing surfaces for damage or scoring. Lubricate new O-rings with clean PAG oil compatible with R-1234yf systems and electric vehicle compressors. Install the new O-rings in their grooves, ensuring they are seated properly without twists or damage.
- 7Install the new orifice tubeLubricate the new orifice tube O-rings with clean PAG oil. Note the directional arrow on the orifice tube body - it must point in the direction of refrigerant flow toward the evaporator. Insert the orifice tube straight into the line until it seats completely. The tube should be fully inserted with the tabs properly positioned to prevent it from backing out.
- 8Reconnect the liquid lineAlign the liquid line connections and push together firmly until you hear or feel the locking mechanism engage. Pull on both sides of the connection to verify it is fully locked. The connection should not separate under moderate pulling force. Verify the O-rings did not roll or pinch during connection.
- 9Add replacement PAG oilAdd the appropriate amount of PAG oil to compensate for oil lost during the procedure. For orifice tube replacement, typically 1-2 ounces is sufficient unless significant oil was lost. Use only PAG oil specified for electric vehicle AC compressors and R-1234yf systems. Add through the low side service port or compressor fill port as applicable.
- 10Evacuate the systemConnect the vacuum pump to the AC service ports through the manifold gauge set. Evacuate the system to at least 29 inches of mercury vacuum. Maintain this vacuum for a minimum of 45 minutes for the Rivian EDV 500 system. After evacuation, close the valves and monitor for 10 minutes - vacuum should hold steady indicating no leaks.
- 11Recharge the AC systemUsing the AC recharge machine, add R-1234yf refrigerant to the system. Charge with the amount recovered (if clean) or according to Rivian specifications (typically displayed on the underhood label). Charge through the low side port with the system in service mode. Monitor pressures and ensure refrigerant is entering the system properly.
- 12Reconnect electrical systemsExit service mode on the Rivian vehicle interface. Reconnect the 12-volt auxiliary battery negative terminal. Wait for the vehicle systems to initialize fully. Verify no warning lights are illuminated on the instrument cluster related to the AC or high voltage systems.
Reassembly
- Reinstall any protective covers or panels removed during access
- Verify all AC line connections are secure and properly locked
- Check that no tools or materials were left in the engine compartment
- Ensure high voltage system lockout devices are removed if used
Verification
- Start the vehicle and enable the AC system at maximum cooling
- Verify compressor engages and system operates smoothly without unusual noises
- Check that both high and low side pressures are within specification using manifold gauges (typically 35-55 PSI low side, 180-250 PSI high side at 75°F ambient)
- Confirm cold air output at dashboard vents reaches appropriate temperature (typically 38-45°F)
- Inspect all connection points for signs of refrigerant leakage using electronic leak detector or UV dye
- Use scan tool to verify no AC-related fault codes are present
- Test system operation through multiple modes (vent positions, temperature settings) to ensure proper function
- Allow system to run for 10-15 minutes and recheck pressures for stability